Nano Accuracy, Every Needle Delivers Precision
Latest Collection
-
Magnetic Separation Aspirate Needle
Precision magnetic-separation aspirate needle — inert low-binding bore prevents bead adsorption, dual external + through-needle wash for ultra-low carryover, OEM-grade drop-in fit and repeatable volume.
-
Coagulation Reagent Needle with stirring function
Coagulation reagent needle with stirring function — dispensing and mixing in one probe, with OEM-true straightness and concentricity for uniform stirring, a fibrin-resistant 316L surface, and ultra-low carryover.
-
Chemiluminescence Sample Needle
Precision CLIA sample needle — inert low-binding bore prevents residue, dual external + through-needle wash for ultra-low inter-sample carryover, OEM-grade drop-in fit and repeatable volume.
-
Reagent Needle for Sysmex-CA500
Reagent needle for the Sysmex CA-500 series — compatible replacement for P/N 663-0190-8. Precision reagent dispensing with a corrosion-resistant 316L bore, ultra-low carryover, and OEM-grade drop-in fit.
Testimonials
Nano Accuracy, Every Needle Delivers Precision&Endurance
Latest From The Blog

Material & Surface Requirements
The internal bore must be extremely smooth, with minimal adsorption of biomolecules such as proteins and nucleic acids. This prevents analyte loss (falsely low results) and carryover between samples. The outer wall needs wear-resistant treatment too — plus low adsorption and easy cleaning. Chemically, the material must withstand acids, alkalis, and organic solvents. Corrosion or dissolution would contaminate the sample or inhibit the reaction. A tapered, thin-walled design helps empty the liquid completely, minimizing dead volume.

Piercing Probe Wear & Service Life
The piercing probe repeatedly pierces the rubber stopper of vacuum blood collection tubes, which wears on the needle. After too many punctures, the tip may lose its sharpness — or the aspiration orifice may deform. That's why piercing probes have a finite service life. They're consumables and must be replaced periodically. Extending probe life calls for a special wear-resistant coating. With a special alloy and a unique DLC (diamond-like carbon) coating, the probe is engineered for up to 100,000 punctures.

Accuracy, Liquid-Level Detection & Lot Consistency
Dispensed volume must match the nominal volume — the deviation has to be minimal. Even a small volume error shifts reaction concentrations. That's how false results creep in. Liquid-level detection is automatic. The tip never plunges too deep, never sucks air. Aspiration stays accurate. So does efficiency. Precision dimensions mean a stable, accurate fit in any automated analyzer — no wobbling, no misalignment. Every performance parameter must hold tight — within a lot, and across lots. That consistency is what makes results reliable and comparable.